Fixed Height Units (Carpeted) |
 LEG STRUCTURE (Fixed Height)
Each leg assembly shall be constructed of 1.05" diameter, 14 gauge steel tubing capped at the point of floor contact with high impact plastic glides. The vertical load bearing members shall be joined at the top by a full width, steel tube to provide maximum support to the stage deck. The top of each leg assembly shall fold open and closed, rotating within 16 gauge steel saddle clips that are secured with at least four screws. Leg assemblies shall be braced by friction type braces, equipped with a spring locking device to secure the legs in the open and closed position. Braces shall be secured to the leg assembly with rivets and to the decking using a minimum of six screws and two bolts installed through the decking. It shall require only three leg assemblies to fold when opening or closing each riser unit. Legs shall open and close using only one hand. Gravity ring type brace locks are not acceptable.
|